Prefabricated Vertical Drains (PVDs)
GeoDrain PVD is a prefabricated band drain - a corrugated or fishbone polypropylene core wrapped in a filter geotextile - installed vertically into soft, compressible ground. It shortens the pore-water drainage path from metres to centimetres, cutting consolidation of soft clays and silts from years to months under surcharge or vacuum preload. Supplied in 100 mm widths, 300–350 m rolls, with discharge capacities to 100 × 10⁻⁶ m³/s at 300 kPa.
Technical Specification of Prefabricated Vertical Drains (PVDs)
Prefabricated vertical drains (PVDs), also called band drains or wick drains, are geocomposite strips installed vertically into soft, compressible soils to accelerate consolidation. Each drain consists of a channelled polypropylene core wrapped in a filter geotextile: the core carries pore water vertically to a surface drainage blanket, while the filter admits water and excludes soil fines that would otherwise clog the flow channels. Because consolidation time varies with the square of the drainage path length, replacing a vertical path of several metres with a horizontal path of under a metre reduces primary settlement time from years to a matter of months.
GeoDrain PVD uses a polypropylene core in two channel geometries. The corrugated core presents continuous parallel flow channels on both faces and is the general-purpose configuration for most embankment and reclamation work. The fishbone core uses a herringbone channel pattern that maintains flow paths under lateral confinement and drain buckling at depth. Both are 100 mm wide (±3.0 mm) with a nominal 3.0–4.0 mm thickness, and are wrapped in a nonwoven filter — polypropylene or polyester depending on grade - selected for an apparent opening size of 75 microns or finer to retain fines while sustaining permeability under confining stress.
PVD design is governed by drain spacing rather than drain capacity in most soils. Spacing is set from the target degree of consolidation and the available preload period using radial consolidation theory (Barron, Hansbo), with typical grids of 0.8 m to 2.0 m in triangular or square patterns; triangular gives more uniform pore pressure dissipation for the same drain count. Three effects should be checked against the datasheet values: well resistance, where discharge capacity must remain adequate at the design confining pressure and at depth; smear, the remoulded annulus created by mandrel penetration, which reduces horizontal permeability near the drain; and filter retention against the in-situ particle size distribution.
PVDs are specified wherever soft clays, silts or hydraulically placed fills must gain strength and complete settlement before permanent works proceed — port and container terminal reclamation, highway and rail embankments on soft ground, storage tank and warehouse pads, tailings and landfill platforms, and airport aprons. Installation depths of 10–25 m are routine, with 40 m achievable on suitable rigs. PVDs do not by themselves cause settlement: they provide the drainage path, and a driving load must be applied by surcharge preload, staged embankment construction, or vacuum consolidation. Design should always pair drain layout with a surcharge programme and an instrumentation regime of settlement plates and piezometers.
Typical Values for PIPES DRAINAGE DUCTING
Properties & Dimensions
| Property | Test Method | Unit | GD-3070C / 3070F | GD-3520U | GD-3540T |
|---|---|---|---|---|---|
| Core / filter material | - | - | PP / PET | PP / PP | PP / PP |
| Width | IS 1954 | mm | 100 ±3.0 | 100 ±3.0 | 100 ±3.0 |
| Thickness, min | ASTM D 5199 | mm | 3.0 ±0.5 (core) | 4.0 (overall) | 4.0 (overall) |
| Discharge capacity — straight, 300 kPa, i=1.0 | ASTM D 4716 | ×10⁻⁶ m³/s | 100 | 90 | 80 |
| Tensile strength, full width, min | ASTM D 4595 | kN | 2.5 | 1.5 | 2.0 |
| Filter tensile (MD), min | ASTM D 4595 | kN/m | 6.0 | 3.0 | 6.0 |
| Apparent opening size (O₉₀), max | ASTM D 4751 | Micron | 75 | 75 | 75 |
| Roll length | IS 1954 | m | 300 / 350 | 200 / 250 / 300 | 200 / 250 |
Popular Catalogue Items
Related Product Groups
Three Questions To Ask Before You Order
1.What is a prefabricated vertical drain (PVD)?
2.How much faster do PVDs make consolidation?
3.What is the typical PVD spacing?
4.Do PVDs work without a surcharge?
5.How deep can PVDs be installed?
6.What is the difference between corrugated and fishbone PVD cores?
7.What discharge capacity does a PVD need?
8.What is the smear zone and why does it matter?
9.How are PVDs spliced and installed?
10.What should I specify when ordering PVDs?
Specification For The Design, Installation Of Prefabricated Vertical Drains (PVDs)
Installation begins with a working platform and a horizontal drainage layer. The platform must carry the rig, typically 30 to 60 tonnes on tracks, over ground that is by definition soft - this usually means a granular fill layer, often reinforced with a woven geotextile or geogrid separator to prevent loss of fill into the subgrade. The same layer serves as the drainage blanket that receives water discharged by the drains, so it must be free-draining sand or aggregate, generally 0.5 to 1.0 m thick, with an outlet to collection drains or a filter-protected edge. Water discharged from the drains has nowhere to go without a functioning blanket, and a blocked or contaminated blanket is one of the most common causes of underperformance on site.
The drain grid is set out to the design spacing and pattern, with each position marked and referenced. Drain is threaded through a hollow steel mandrel and secured at the base with a disposable anchor plate or shoe, sized to grip the soil on withdrawal and to seal the mandrel against soil ingress. The mandrel is driven to design depth by static push or vibration, then withdrawn, leaving the drain anchored at depth. The drain is cut off 150 to 300 mm above the blanket surface so it discharges freely into it. Where a roll is exhausted mid-drain, splices are made by overlapping 200 to 300 mm with core over core and filter over filter, secured so the flow channel remains continuous and soil cannot enter at the joint.
Drains alone do not produce settlement; a driving load must be applied. Surcharge is placed as fill above the drainage blanket to the design height, or vacuum consolidation is applied beneath a sealed membrane where surcharge fill is unavailable or stability limits its height. On soft deposits, surcharge is usually raised in stages, with each lift held until the underlying soil has gained sufficient shear strength to permit the next - placing fill faster than strength develops is the principal cause of embankment failure on PVD-treated ground. Surcharge height and duration are set together with drain spacing in design, and one cannot be varied on site without reassessing the other.
Performance is verified by instrumentation, not assumed. Settlement plates track surface movement, piezometers record pore pressure dissipation in the treated stratum, and inclinometers monitor lateral movement at the embankment toe where stability governs. Settlement and pore pressure data are used to estimate the degree of consolidation achieved, commonly by Asaoka or hyperbolic methods, and surcharge is released on that evidence rather than on elapsed time. Installation records for each drain - position, depth achieved, date and any obstruction or refusal - together with the instrumentation record form the acceptance documentation for the works.
Featured Projects Across Africa
Related Resources
Common PREFABRICATED VERTICAL DRAINS PVDS Applications
Request a Quote for This Product Family
Upload your BOQ, drawings, or specifications and our technical team will provide a detailed proposal.
Have a project? Start with us.
Get expert engineering support, reliable material supply, and best-in-class installation.