IAGI Installer Member
IAGI Member · One of only 5 in Africa

Quality Assurance That Protects People, Projects, and the Environment

Geosynthetics Africa applies documented quality control from material verification through installation and handover. As an IAGI Installer Member, we support recognised installation practices, with inspection and testing requirements defined by the project specification, manufacturer guidance and agreed QA/QC plan. Seam test records and material traceability form part of the project documentation.

Material Verification - virgin-grade, certified products with full mill certificate traceability
IAGI Installer Member — committed to recognised geosynthetic installation practices
On-Site QA/QC — non-destructive seam testing and destructive sampling to the approved project QA/QC plan
Handover Dossier — installation records, test results, material certificates and as-built documentation within the agreed scope
100+
Projects Delivered - Across mining, water, waste, energy, and civil infrastructure
30+
African Countries Covered - Southern, East, Central and West Africa
100%
Non-Destructive Seam Testing — geomembrane seams tested using the applicable method under the approved project QA/QC plan
IAGI
Installer Member — supporting recognised installation practices
15
Certified Welders — supported by ongoing in-house training and continuing professional development
QA/QC
Records — documented inspections, seam testing and installation records compiled into the project handover dossier
Our QA/QC Process

A Quality Framework Built for Africa's Most Demanding Projects

Material Receiving & Verification

Every consignment is verified against the project specification before a single roll is accepted on site. We check manufacturer mill certificates, conformance test reports, roll numbers, and product datasheets - confirming virgin-grade material, correct specification, and compliance with GRI-GM13 or the applicable standard. If it does not pass receiving inspection, it does not go into the ground.

Pre-Installation Engineering Review

Before installation begins, our team reviews panel layouts, anchor trench details, subgrade condition, drainage requirements and site-specific risks within the agreed scope. Identified issues are referred for resolution before the affected installation work proceeds.

Manufacturer-Aligned Installation Standards

Installation follows the applicable manufacturer guidelines and approved project specification for each system. Our certified welders receive ongoing in-house continuing professional development covering installation practices, quality control, health, safety and environmental requirements.

Seam Testing - Non-Destructive & Destructive

Geomembrane seams undergo non-destructive testing using the applicable method: air-channel pressure testing for dual-track fusion seams under ASTM D5820, and vacuum-box testing of suitable extrusion seams under ASTM D5641/D5641M. Destructive samples are taken at intervals defined in the approved project QA/QC plan and evaluated for peel and shear strength under ASTM D6392. Results are recorded by seam, technician, date and outcome. Failed areas are repaired and retested before acceptance.

On-Site Quality Control & Independent Review

Our installation teams undertake documented quality control, including subgrade inspections, weld-condition checks, anchor trench and penetration inspections, and site QC records as required by the approved project QA/QC plan. Independent third-party review is provided where required by the project specification or agreed scope.

Handover Dossier & Full Traceability

Every project closes with a complete handover dossier — the definitive record of what was installed, where, by whom, and to what standard. Contents include as-built panel layout drawings, all seam test records, manufacturer certificates with roll-to-panel traceability, photographic documentation of key installation stages, and a signed conformance statement. A document package built to last as long as the structure it covers.

QA Documentation

QA by Product & System

Select a product line or programme to explore the specific quality assurance documentation, standards, and processes we apply.

Request Full QA Dossier
GSE® / Solmax Geomembrane Installtion Quality Assurance
Solmax Manufacturer Standard · IAGI-Aligned Installation

GSE® / Solmax Geomembrane Installtion Quality Assurance

Geosynthetics Africa installs GSE® HDPE geomembranes to the full Solmax Installation QA Manual standard - 12-stage process, 100% weld testing, destructive coupon sampling, and complete as-built documentation on every project.

View GSE® QA Documentation
Eurobent® GCL Quality Assurance
Eurobent® Manufacturer Standard · GRI GCL-3 · EN 13361 / EN 13492 / EN 13493

Eurobent® GCL Quality Assurance

Geosynthetics Africa installs Eurobent® Geosynthetic Clay Liners in strict accordance with the Eurobent GCL Drop IN Installation Manual - from certified subgrade preparation and controlled panel deployment through to bentonite overlap management, hydration protocol, and complete project documentation. Every roll traced. Every overlap verified. Every installation covered before end of working day.

View Eurobent® QA Documentation
Tensar® Geogrids Quality Assurance
BS/ASTM Certified

Tensar® Geogrids Quality Assurance

Geosynthetics Africa installs Tensar® geogrids in line with manufacturer guidelines and verified performance requirements for soil reinforcement and ground stabilisation.

View Tensar® QA Documentation
Geosynthetics Africa Quality Assurance
Integrated Manufacturer & IAGI-Aligned Standard · Best-in-Class Delivery

Geosynthetics Africa Quality Assurance

Geosynthetics Africa combines applicable manufacturer guidance, project specifications and documented QA/QC procedures to control installation quality. Inspection, testing, material traceability and handover records are defined by the agreed project scope.

View QA Documentation
IAGI Membership
IAGI Installer Member · One of Only 5 in Africa

IAGI Membership

Geosynthetics Africa is an IAGI Installer Member, supporting recognised geosynthetic installation practices. Membership is separate from technician certification and Approved Installation Contractor status, and does not constitute certification or supervision of individual projects.

View IAGI Membership Details
IAGI Member — One of only 5 in Africa

IAGI Membership. Documented Installation Quality.

The International Association of Geosynthetic Installers (IAGI) promotes good practice in geosynthetic installation. Geosynthetics Africa is an IAGI Installer Member. Membership is distinct from IAGI Certified Welding Technician certification and Approved Installation Contractor status; it does not mean IAGI supervises or certifies individual projects. Our work is controlled through applicable manufacturer guidance, project specifications and the approved QA/QC plan, supported by documented inspections, seam testing, material traceability and handover records. Independent third-party review is provided where required by the project specification or agreed scope.

IAGI
Installer Member — committed to recognised geosynthetic installation practices
CPD
In-House Training — installation practices, quality control, health, safety and environment
QA/QC
Project Records — inspections, seam testing and material traceability within the agreed scope
100+
Projects Delivered — across mining, water, waste, energy and civil infrastructure

Submit your BOQ.

Get a quote – not just a price.

Upload your BOQ or speak to our technical team for expert recommendations and support.

Quick Contact

Global Best-in-Class Materials

Integrated into engineered systems

AmourRock logo
SoilLock logo
FlowTex logo
PolyTape logo